Multimeter UNI-T UT202R clamp

€66.69
Tax included
50 Items
TP-07720255-EU
Quantity
Delivery 7 - 12 working days

  Saugus Atsiskaitymas

El. Bankininkystė, Grynais arba Visa - Mastercard

  Nemokamas Pristatymas

Nemokamas pristatymas užsakymams nuo 59€.

  Nemokamas Grąžinimas

Suteikiame 14 dienų pinigų grąžinio garantiją

Multimeter UNI-T UT202R clamp
The digital clamp meter UT202R is used for measuring AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It has protection against voltages higher than 600V on all ranges and an audible and optical alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlight and fast refresh rate (3 times / s). The opening of the jaws allows measurement on cables with a diameter of up to 28 mm. Non-contact electric field sensing (NCV) allows to detect live conductors in two sensitivities -EFLo and - EFHi for low voltage distribution 110V / 50 / 60Hz and 230V / 50 / 60Hz. Supplied probe - tip cover on test cables allows measurement on LV distribution in CAT III category without the risk of arcing. Without covers on the tips, test cables can only be measured on low-voltage distribution lines of CAT II category. Power battery 2pcs 1.5V R03. The power consumption of the meter is approx. 1.8 mA. The circuit has an automatic energy saving function. Sleep consumption is <11μA, which effectively extends battery life to approximately 400 hours.


Product parameters:

- measurement of voltage, current and frequency of high voltage up to 600 V
- non-contact electric field sensing (NCV)
- temperature measurement -40°C to 1000°C
- multi-segment display and audible / visual alarm
- protection against voltages greater than 600V across ranges
- automatic range switching
- accuracy is guaranteed in the range of 1% to 100% of the range


Technical parameters:


1. AC current measurement (ranges / resolution / accuracy):

4,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% +10)
40.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +10)
400.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% +10)
- frequency monitoring accuracy when measuring AC current in the range of 50 to 100Hz is ± (1.0% + 5) at 0.1Hz resolution
- overload protection at 420A


2. AC voltage measurement (range / resolution / accuracy):

4.000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
40.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% +5)
400.0V / 0.100V / 10Hz ~ 10kHz ± (0.8% +5)
600.0V / 1,000V / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range of 10Hz to 10kHz ± (1.0% + 5) at a resolution of 0.01Hz to 0.01kHz
- overload protection at 600Vrms
- input impedance approx. 10MGΩ


3. DC voltage measurement (range / resolution / accuracy):

400.0mV / 0.100mV / ± (0.7% +3)
4.000V / 0.001V / ± (0.5% +2)
40.00V / 0.010V / ± (0.7% +3)
400.0V / 0.100V / ± (0.7% +3)
600V / 1,000V / ± (0.7% +3)
- input impedance approx. 10MΩ
- overload protection at 600Vrms


4. Resistance measurement (ranges / resolution / accuracy):

400.0Ω / 0.1Ω / ± (1.0% +2)
4,000kΩ / 0.001kΩ / ± (0.8% +2)
40.00kΩ / 0.01kΩ / ± (0.8% +2)
400.0kΩ / 0.1kΩ / ± (0.8% +2)
4,000MΩ / 0.001MΩ / ± (2.0% +5)
40.00MΩ / 0.01MΩ / ± (2.0% +5)
- overload protection at 600 Vrms


5. Capacity measurement (ranges / resolution / accuracy):

4,000nF / 0.001nF / ± (4.0% +10)
40.00nF / 0.01nF / ± (4.0% +10)
400.0nF / 0.1knF / ± (4.0% +10)
4,000μF / 0.001μF / ± (4.0% +5)
40.00μF / 0.01μF / ± (4.0% +5)
400.0μF / 0.1μF / ± (4.0% +5)
4,000mF / 0.001mF / ± 10.0%
- overload protection at 600 Vrms


6. Temperature measurement (ranges / resolution / accuracy):

-40°C to +40°C/1°C / ±4°C
+40°C to +500°C/1°C/ ±(1.5% +5)
+500°C to +1000°C/1°C/ ±(2.0% +5)

-40°F to +104°F/1°F/ ± 6 ° F
+104°F to +932°F/1°F/ ± (2.0 +6)
+932°F to +1832°F/1°F/ ± (2.5% +4)



7. Circuit continuity check:

- if the measured resistance is less than 10Ω, the signal of the continuous circuit sounds a buzzer
- if the measured resistance is greater than 31alizace, the open circuit signal does not sound a buzzer
- open circuit voltage about 2.0V
- measurement in the range of 400Ω
- overload protection at 600 Vrms


8. Diode measurement:

- in the forward direction, the voltage drop of the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open circuit voltage about 2.2V
- measurement in the range of 4,000V


9. Contactless electric field sensing (NCV):

- allows to detect live wires in two sensitivities - EFLo and - EFHi for low voltage distribution 110V / 50 / 60Hz and 230V / 50 / 60Hz


Other parameters:

- measurement of maximum and minimum values: Yes​​
- HOLD: Yes
- low battery indication: Yes
- automatic power off: Yes
- battery supply 1.5 V (R03): 2pcs
- backlit display size: 37 mm x 25 mm
- product dimensions: 215 mm x 63 mm x 36 mm
- net weight of the product: 248 g
- product color: red and gray


Package contents:

- clamp multimeter UT202R: 1pc
- test leads: 1 pair
- battery 1.5 V (R03): 2pcs
- instructions for use: 1pc



Wholesale packaging:

- standard quantity per carton: 40pcs
- standard carton dimensions: 485 mm x 295 mm x 385 mm
- standard gross carton weight: 17.1 kg


MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
TP-07720255-EU
50 Items
TP-07720255-EU

Specific References

New Account Register

Already have an account?
Log in instead Or Reset password