MPPT "Victron Energy SmartSolar" 150V / 35A "Bluetooth" saulės

MPPT "Victron Energy SmartSolar" 150V / 35A "Bluetooth" saulės valdiklis

242,93 €
Su PVM
4 Vnt.
TP-04280190-EU
Kiekis
Pristatymas 7 - 12 darbo dienos

  Saugus Atsiskaitymas

El. Bankininkystė, Grynais arba Visa - Mastercard

  Nemokamas Pristatymas

Nemokamas pristatymas užsakymams nuo 79€.

  Prekių Grąžinimas

Suteikiame 14 dienų pinigų grąžinio garantiją


Robust and fast MPPT regulator for demanding conditions with panel voltage up to 150V, maximum charging current 35 A. Battery 12/24 / 48V, PV max 500/1000 / 2000Wp. Full warranty 5 years. Integrated bluetooth.

As proof of the high quality of all MPPT controllers, Victron Energy provides an extended full 5-year warranty.

Victron Energy MPPT solar controllers are among the absolute world leaders in this field. It offers ultra-fast MPPT monitoring, which ensures the maximum possible solar gains. Especially in cloudy weather with frequent changes in exposure intensity, solar gains are 30% higher compared to conventional PWM controllers or 10% higher compared to slower MPPT controllers.

The maximum power of solar panels is 500 Wp for 12 V systems, 1000 Wp for 24 V systems and 2000 Wp for 48 V systems. If these values ​​are exceeded, the controller will not be damaged, but will only automatically reduce the incoming power from the panels to acceptable values. The solar controller is factory preset for eight types of batteries - the selection of the appropriate type is made using a rotary switch located on the body of the controller.

The maximum no-load voltage (referred to as Voc) of the connected solar panels must not exceed 150V (attention: the voltage of the solar panels increases with decreasing outdoor temperature). The maximum input short-circuit current of the PV modules must not exceed 40A, otherwise permanent damage may occur.

Check the correct choice of your BlueSolar / SmartSolar controller according to the parameters of the photovoltaic field in our configurator here

The new range of SmartSolar MPPT controllers offers built-in Bluetooth
This new feature brings the ability to connect your "smart" phone / tablet to your "smart" solar controller.
You can monitor many system parameters and historical statistics for the last 30 days. You also have the option of setting operating parameters.

If you want to do the above using a PC, then you have the option to use a VE.direct to USB cable to connect the controller and PC. You will only install the Victron Connect program on your computer, which you can download for free again at the same address here.

Internal electronic components are protected by a resin coating against adverse effects and for long life. It thus offers increased IP43 protection for electronic components and IP22 for connection connectors. Designed for vertical positioning on a non-flammable surface, with wiring from below.

The controller contains an internal temperature sensor for appropriate adjustment of the charging voltage. Automatic detection of system voltage 12/24/48 V.

Adaptive three-stage charging:
1. Bulk, 2. Absorption and 3. Float. Initially, fast charging generates high current and lower voltage to quickly charge a discharged battery. This phase is followed by a constant voltage with decreasing current to fully charge the battery without dangerous overcharging, reducing battery life. A charged battery is kept charged with very low current and low voltage. If the battery voltage drops below 13.2 V, for example due to a load, a new charging cycle is started.

The voltage from the panels must exceed the battery voltage by 5 V for the controller to start working and charge the battery. The controller charges until the voltage from the panels is 1 V higher than the battery voltage. For a 12 V battery, we recommend panels with a minimum number of 32 cells and a maximum number of 108 cells (panels in series). It is therefore possible to charge a 12 V battery as well as panels with a working voltage of 24 V. For 24 V systems, we recommend panels with a minimum number of 72 cells and a maximum number of 108 cells. The purpose is to achieve sufficient voltage for efficient and full battery charging.

This more powerful range of solar controllers is not equipped with a DC output. We recommend using "BP battery protection" with a maximum load current of up to 220A to connect the DC load to the battery.
VICTRON ENERGY
TP-04280190-EU
4 Vnt.
TP-04280190-EU

Specifiniai Kodai

Naujos Paskyros Kūrimas

Jau turite paskyrą?
Prisijungti Arba Priminti slaptažodį