Silicone neutral PENOSIL Premium transparent 310ml

5,90 €
Brutto
TP-06560580-EU
Ilość
Obecnie brak na stanie

  Saugus Atsiskaitymas

El. Bankininkystė, Grynais arba Visa - Mastercard

  Nemokamas Pristatymas

Nemokamas pristatymas užsakymams nuo 59€.

  Nemokamas Grąžinimas

Suteikiame 14 dienų pinigų grąžinio garantiją


One-component silicone sealant with good processing properties, excellent adhesion and a wide range of applications. Insulates and seals both indoors and outdoors. It adheres to most building materials, such as stone, metal and wood materials, glass and plastic surfaces. Suitable for slightly alkaline, metal surfaces. Adheres well to porous surfaces. Resistance to mold, UV radiation, humidity and weathering. Excellent processing and smoothing properties. Slight odor.

Use
Insulation and sealing of joints during routine construction and repair work. Also on surfaces where acid-curing silicone cannot be used, eg sheet metal and ventilation work, etc. All finishing, insulation and ventilation work.

Application procedure
Application temperature between + 5 ° C and + 40 ° C. The application temperature of the sealant must be +20 ° C - +25 ° C. Application at temperatures below +5 ° C can only be carried out when the attached surfaces are free of condensation, snow and ice. Not suitable for sealing aquariums and for underwater use. Cannot be painted.

Surface preparation:
Surfaces must be cleaned of dust, loose particles and oil. Non-porous surfaces should be cleaned with a solvent and a clean, lint-free cotton cloth. Residual solvent must be removed with a clean cloth before evaporation.
310 ml cartridge: Cut off the threaded end of the cartridge and screw on the application nozzle to direct the sealant. Cut the threaded end to make a suitable hole for the application. Insert the cartridge with the applicator into the gun and press the trigger of the gun repeatedly to fill the installation nozzle with sealant.
600 ml foil pack: Open the gun application nozzle, insert the pack into the gun, and open the applicator side by removing the retaining clip. Place the application nozzle on the open end and screw on the cap. Apply sealant to the joint by repeatedly and evenly pressing the trigger of the gun and smoothly pulling the nozzle across the joint. After application, smooth the surface with a rubber silicone scraper and remove excess material. Ensure adequate ventilation at all joints. During curing, make sure that no dirt settles on the surface and that the joint surface is not mechanically stressed.

Cleaning:
Uncured sealant, tools and hands can be cleaned with PENOSIL Premium cleaning wipes. Hardened sealant can be removed mechanically with PENOSIL Premium Silicone Remover to soften the sealant. Clean the surface with a sponge and water.

Technical parameters:

- Structure creation time min. 13-15
- Curing time mm / 24 h 2.5–3
- Density (DIN 53 479-B) g / cm3
- 0.99 - transparent
- 1.26 - color
- Properties of hardened sealant
- Joint movement, ISO 11600% ± 12.5
- Microbiological growth intensity, ISO846 0+
- Flow resistance, ISO7390 mm 0
- Volume change, ISO10563%
- 25 ± 1 - transparent
- 20 ± 1 - color
- Elongation at break, ISO37%
- 525 ± 25 - transparent
- 400 ± 25 - color
- Tensile strength, ISO37 N / mm2
- 1.4 ± 0.2 - transparent
- 2,5 ± 0,2 - color
- Module at 100% elongation, ISO 37 N / mm2
- 0.5 ± 0.1 - transparent
- 1.1 ± 0.1 - color
- Hardness (Shore A)
- 35 ± 2 - transparent
- 45 ± 2 - color
- Temperature resistance ° C -40 to +100
(- The stated parameters were measured at a temperature of +23 ° C and a relative humidity of 50%.)

Safety regulation:
Ensure adequate ventilation during application. Keep out of reach of children. Avoid contact with skin and eyes. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. The hardened sealant can be handled without endangering health. Detailed safety information is available in the Safety Data Sheet (SDS).