3F DIN rail meter MID-FM-3D
59,08 €
Brutto
TP-07750140-EU
El. Bankininkystė, Grynais arba Visa - Mastercard
Nemokamas pristatymas užsakymams nuo 59€.
Suteikiame 14 dienų pinigų grąžinio garantiją
3F DIN rail meter with MID certificate
The electricity meter can be used as a benchmark to measure active energy for use in residential, commercial and light industry.
Product parameters:
- three-phase, four-wire design
- DIN rail mounting
- digital display
- wide range of current measurement
- Used as a recording device, can not be reset
- LED indication of phase control, pulse frequency, backflow current
- pulse output
- small dimensions, low weight
- low power consumption
- easy installation
Technical parameters:
- International Standard: EN 50470 , MID
- protection against moisture and dust: IP51 (with protective cover)
- accuracy class: 1
- Maximum voltage (Un): 3 x 230 V / 400 V AC (3 ~)
- voltage range: 161 V / 279 V - 300 V / 500 V AC (3 ~)
- Base current (Ib): 5 A
- maximum current (Imax): 100 A
- Startup current: 0.4% Ib
- Operating frequency: 50 Hz
- internal energy consumption: ≤ 2 W / 10 VA each phase
- Output pulse frequency: 400 pulses / kWh
- Working relative humidity: ≤ 75%
- Storage relative humidity: ≤ 95%
- Operating temperature: -10 ° C to + 50 ° C
- Storage temperature: - 30 ° C to + 70 ° C
- Dimensions: 110 x 70 x 64.5 mm
- weight: 0,5 kg (net weight)
The electricity meter can be used as a benchmark to measure active energy for use in residential, commercial and light industry.
Product parameters:
- three-phase, four-wire design
- DIN rail mounting
- digital display
- wide range of current measurement
- Used as a recording device, can not be reset
- LED indication of phase control, pulse frequency, backflow current
- pulse output
- small dimensions, low weight
- low power consumption
- easy installation
Technical parameters:
- International Standard: EN 50470 , MID
- protection against moisture and dust: IP51 (with protective cover)
- accuracy class: 1
- Maximum voltage (Un): 3 x 230 V / 400 V AC (3 ~)
- voltage range: 161 V / 279 V - 300 V / 500 V AC (3 ~)
- Base current (Ib): 5 A
- maximum current (Imax): 100 A
- Startup current: 0.4% Ib
- Operating frequency: 50 Hz
- internal energy consumption: ≤ 2 W / 10 VA each phase
- Output pulse frequency: 400 pulses / kWh
- Working relative humidity: ≤ 75%
- Storage relative humidity: ≤ 95%
- Operating temperature: -10 ° C to + 50 ° C
- Storage temperature: - 30 ° C to + 70 ° C
- Dimensions: 110 x 70 x 64.5 mm
- weight: 0,5 kg (net weight)